On 17 September, the Finland-headquartered group behind Tylö and Helo recalled 48,000 saunas across the US and Canada for a fire risk, the same day it admitted an eleven-month-old fix for a separate collapsing-bench hazard had already failed on 77 more units
On 17 September 2026, Sauna360, the Finland-headquartered sauna group formed from the 2017 merger of Sweden's Tylö and Finland's Helo, was the subject of two separate hazard actions on the same day, in two different countries, for two different defects. In the United States, the Consumer Product Safety Commission (CPSC) and Sauna360 recalled about 41,580 infrared and hybrid infrared saunas and infrared kits, sold under the Finnleo, Tylö, Polar, Radiant Health and Helo brand names, after finding the infrared panels can short circuit, overheat and pose a fire and burn hazard. The same day, Health Canada published a matching recall covering about 6,758 of the same units sold in Canada. Also on 17 September, in a separate CPSC filing, Sauna360 expanded an October 2025 recall of Tylö Halmstad and Kiruna Hybrid sauna benches, after the free repair it had offered for a collapsing-bench hazard failed to stop the benches from breaking: the company logged 77 further reports, including six injuries, on top of the seven reports and one injury that triggered the original recall eleven months earlier.
What actually happened on 17 September
The fire and burn recall covers infrared and hybrid sauna rooms and standalone infrared kits carrying the Finnleo, Tylö, Polar, Radiant Health or Helo badge, plus custom sauna rooms built with panels marked Saunalogic, Infralogic, Carbonflex or Tylö on the control panel. They were sold at Costco stores and Costco.com, and through pool and spa dealerships nationwide, from May 2013 through July 2026, for between $6,000 and $13,000. In the US, Sauna360 logged 67 reports of the infrared panels overheating, melting, charring or burning, with no injuries reported. In Canada, the company logged 5 reports of incidents as of 10 September 2026, also with no injuries. In both countries, the remedy is the same: consumers must stop using the sauna immediately and contact Sauna360 to schedule a free in-home repair from a professional installer.
The bench recall is a different product line and a different hazard. Tylö Halmstad 2, 3 and 4, and Tylö Kiruna Hybrid 2 and 3 sauna benches were sold from July 2024 through July 2026 for between $6,000 and $12,000. CPSC first recalled the benches on 23 October 2025 after seven reports of collapse, including one consumer with head and neck injuries, and Sauna360 offered a retrofit repair at the time. By 17 September 2026, that repair had not held: the company received 77 more reports of benches breaking, with six injuries, including a second report of head and neck injuries and one sprained ankle. The expanded recall now covers about 6,000 units and comes with a new remedy, a professional retrofit with additional hardware plus a revised manual stating the weight limit; Sauna360 is telling consumers to seek the new repair even if they already received the 2025 fix.
Three details behind the 17 September actions
01
One group, five brand names
Finnleo, Tylö, Polar, Radiant Health and Helo all trace back to Sauna360, the group formed when Tylö and Helo merged in 2017.
02
Two hazards, two markets
The fire and burn recall runs in parallel through CPSC in the US and Health Canada in Canada, each with its own unit count and consumer notice.
03
One repair, now replaced by a second
The bench retrofit issued in October 2025 did not stop further breakages; a revised repair and manual followed eleven months later.
2017
Sweden's Tylö and Finland's Helo merge into TyloHelo, later renamed Sauna360, bringing Finnleo, Polar, Radiant Health, Tylö and Helo under one group.
23 Oct 2025
CPSC and Sauna360 first recall Tylö Halmstad and Kiruna Hybrid sauna benches after seven reports of collapse, including one head and neck injury, and offer a retrofit repair.
17 Sep 2026
CPSC and Health Canada, with Sauna360, recall about 41,580 US and 6,758 Canadian infrared and hybrid saunas and kits for fire and burn risk; the same day, CPSC and Sauna360 expand the bench recall to about 6,000 units after 77 more reports and six injuries, and issue a new remedy.
The numbers behind the two actions
One number is the combined size of the fire and burn recall across both countries. One is how many extra failure reports piled up after the bench fix that was supposed to have closed the earlier hazard. The third is how many months passed between that first fix and the admission that it had not worked.
48,338 units
the combined US (41,580) and Canadian (6,758) recall of infrared and hybrid saunas and kits announced on 17 September 2026 for fire and burn risk
77 more reports
the failures Sauna360 logged on Tylö Halmstad and Kiruna Hybrid sauna benches after its October 2025 retrofit, including six injuries, versus seven reports and one injury before the original recall
11 months
the gap between the original 23 October 2025 bench recall and Sauna360's 17 September 2026 admission that the fix had failed and a new remedy was needed
The real subject: a recall record tracks who was notified, not whether the repair held
Most coverage of 17 September treated the fire recall and the bench recall as two unrelated stories about the same manufacturer, one about defective infrared panels, the other about breaking sauna benches. Read together, CPSC's own record shows something more specific: a repair that a regulator and a manufacturer jointly presented as resolving a hazard, in October 2025, did not survive contact with real use. The retrofit closed the case file, but not the underlying failure mode, and it took 77 more broken benches and six more injuries, tracked only through the company's own incident intake, before a second, different remedy was issued. Nothing in the recall record itself distinguishes a fix that held from a fix that only looked complete until the next incident report arrived. Layered on top of that is the fire and burn recall's own structure: the same hardware platform, sold continuously since 2013 under five brand names, triggers two separate procedural actions, one from CPSC covering roughly 41,580 US units, one from Health Canada covering roughly 6,758 Canadian units, each counted, published and remedied on its own track, with no single cross-border registry linking a specific unit sold in one country to its counterpart sold in the other.
Why it matters for brands
Three groups should read past the headline count of saunas. First, any brand selling one hardware platform under several storefront or regional brand names, as Sauna360 does with Finnleo, Tylö, Polar, Radiant Health and Helo, should treat the underlying component design as the compliance unit that carries risk across markets, not the brand name on the control panel: the same infrared panel defect produced two separately counted, separately published recalls, one under CPSC's US process and one under Health Canada's, with no shared unit identifier between them. Second, a repair is not a closed loop the day it is announced. Sauna360's October 2025 bench fix was represented, at the time, as resolving the hazard; it took eleven months and 77 further failure reports, tracked only through the company's own post-sale incident channel, for that to be shown false. Compliance and product-safety teams should treat post-remedy incident volume as an ongoing signal to monitor, not a metric that stops once a recall notice is published. Third, brands selling comparable sauna heating equipment or infrared cabins into the EU should not assume the fire hazard here is a US-specific story: EN IEC 60335-2-53, the EU-harmonised safety standard for sauna heating appliances and infrared cabins, imposes materially the same protection against overheating and short circuit that the 17 September US and Canadian recalls responded to. The enforcement path differs, EU compliance is typically self-declared through CE marking and checked after the fact by national market surveillance, rather than triggering an immediate recall demand, but the underlying engineering defect, and the cost of a remedy that does not hold, travels with the product regardless of which market's procedure applies.
Two ways to read 17 September
The narrow read
On 17 September 2026, Sauna360 recalled about 48,000 infrared saunas in the US and Canada for a short-circuit fire risk, and separately expanded a sauna-bench recall.
The structural read
The same manufacturer used the same day to disclose a brand-new hazard spanning two countries and five brand names, and to admit that the fix it gave consumers eleven months earlier for a different hazard did not hold, generating 77 more failure reports before it offered a second repair.
Frequently asked questions
What exactly did Sauna360 and regulators announce on 17 September 2026?
Two separate actions. CPSC and Health Canada, together with Sauna360, recalled about 41,580 US and 6,758 Canadian infrared and hybrid infrared saunas and infrared kits, sold under the Finnleo, Tylö, Polar, Radiant Health and Helo brand names, because the infrared panels can short circuit, overheat and cause fire or burns. Separately, CPSC and Sauna360 expanded an October 2025 recall of Tylö Halmstad and Kiruna Hybrid sauna benches to about 6,000 units, after 77 more reports of the benches breaking, including six injuries, and issued a new repair after the 2025 fix failed to stop the failures.
Why did the same company recall two different things on the same day?
The two recalls address unrelated defects on different product lines, infrared heating panels on one side and sauna bench supports on the other, and each moved through its own regulatory timeline before landing on the same publication date. The fire and burn recall is a new hazard finding. The bench recall is the second stage of a hazard first identified in October 2025, reopened because the original retrofit did not prevent further breakages.
Does the EU require the same fire protection on sauna heaters and infrared cabins?
Substantively, yes. EN IEC 60335-2-53, the EU's harmonised safety standard for sauna heating appliances and infrared cabins, imposes protection against overheating and short circuit comparable to the requirement behind the 17 September US and Canadian recalls. The enforcement path differs: EU compliance is typically self-declared through CE marking and checked afterward by national market surveillance authorities, rather than triggering an immediate recall demand from a national safety agency the way CPSC and Health Canada did here.
Sources
- CPSC.gov: "Sauna360 Recalls Infrared Saunas, Hybrid Infrared Saunas and Infrared Kits Due to Risk of Serious Injury or Death from Fire and Burn Hazards," 17 September 2026, on the recalled brand names, US unit count, sale dates, price range and incident count
- Canada.ca (Health Canada recalls and safety alerts): "Finnleo, Tylo, Polar, Radiant Health, and Helo Brand Saunas and Infrared Kits recalled due to fire and burn hazards," on the Canadian unit count and incident count as of 10 September 2026
- CPSC.gov: "Sauna360 Expands Recall of Tylo Halmstad and Kiruna Hybrid Saunas Due to Fall Hazard; New Remedy Provided," 17 September 2026, on the expanded unit count, the 77 additional reports, the six injuries and the new remedy
- CPSC.gov: "Sauna360 Recalls Tylo Halmstad and Kiruna Hybrid Saunas Due to Fall Hazard," 23 October 2025, on the original recall, unit count, sale dates and the seven initial incident reports
- Sauna360: official product recall notice page, corroborating both the infrared/fire recall and the bench recall, the affected brand names and the repair process
- Radiant Health: "Important Safety Notice, Safety Recall for Sauna360 & Radiant Health," the brand's own safety notice corroborating the fire and burn recall and remedy
- Medical Daily: "Tylo Sauna Bench Recall Expands to 6,000 Units After the 2025 Repair Failed and 77 More Benches Broke," independent corroboration of the bench recall expansion, the 77 additional reports and the six injuries
- Yahoo News (wire report): "41,000 Infrared Saunas Sold at Costco Are Recalled After 67 Reports of Overheating and Charring," independent corroboration of the US unit count, incident count, sale dates and price range
- Justia Recalls: "Recall: Sauna360 Recalls Tylo Halmstad and Kiruna Hybrid Saunas Due to Fall Hazard," independent recall-database corroboration of the original October 2025 bench recall
- EN Standard / European Committee for Electrotechnical Standardization: EN IEC 60335-2-53, "Household and similar electrical appliances, Safety, Particular requirements for sauna heating appliances and infrared cabins," on the EU-harmonised overheating and short-circuit protection requirement
- Sauna360: "History," on the 2017 merger of Tylö and Helo into the group now trading as Sauna360, and its Finland headquarters
Note on verification: this session's network access allows search but blocks direct page retrieval from cpsc.gov, canada.ca, medicaldaily.com and most other domains cited above. The recalled brand names, unit counts, sale windows, price ranges and incident counts for the 17 September 2026 fire and burn recall, the 23 October 2025 original bench recall and its 17 September 2026 expansion, were confirmed through search-indexed excerpts of CPSC's and Health Canada's own recall notices, cross-checked against Sauna360's and Radiant Health's own recall and safety-notice pages, Medical Daily's independent report on the bench recall expansion, an Associated Press wire report on the fire and burn recall syndicated by Yahoo News and multiple broadcast affiliates, and Justia's independent recall database entry for the original bench recall. The 2017 merger of Tylö and Helo and the group's Finland headquarters were confirmed through Sauna360's own history and about pages. The EU's EN IEC 60335-2-53 overheating and short-circuit protection requirement for sauna heating appliances and infrared cabins was confirmed through its own standards-body publication listing, without citing a specific clause number that could not be independently cross-checked. Where a figure or claim could not be cross-checked across at least two independent sources, it has been left out of this article. This article names cpsc.gov, canada.ca and en-standard.eu as the underlying primary sources and gives their addresses above for independent verification, since this session could not retrieve their page content directly.
Frequently asked questions
What exactly did Sauna360 and regulators announce on 17 September 2026?
Two separate actions. CPSC and Health Canada, together with Sauna360, recalled about 41,580 US and 6,758 Canadian infrared and hybrid infrared saunas and infrared kits, sold under the Finnleo, Tylö, Polar, Radiant Health and Helo brand names, because the infrared panels can short circuit, overheat and cause fire or burns. Separately, CPSC and Sauna360 expanded an October 2025 recall of Tylö Halmstad and Kiruna Hybrid sauna benches to about 6,000 units, after 77 more reports of the benches breaking, including six injuries, and issued a new repair after the 2025 fix failed to stop the failures.
Why did the same company recall two different things on the same day?
The two recalls address unrelated defects on different product lines, infrared heating panels on one side and sauna bench supports on the other, and each moved through its own regulatory timeline before landing on the same publication date. The fire and burn recall is a new hazard finding. The bench recall is the second stage of a hazard first identified in October 2025, reopened because the original retrofit did not prevent further breakages.
Does the EU require the same fire protection on sauna heaters and infrared cabins?
Substantively, yes. EN IEC 60335-2-53, the EU's harmonised safety standard for sauna heating appliances and infrared cabins, imposes protection against overheating and short circuit comparable to the requirement behind the 17 September US and Canadian recalls. The enforcement path differs: EU compliance is typically self-declared through CE marking and checked afterward by national market surveillance authorities, rather than triggering an immediate recall demand from a national safety agency the way CPSC and Health Canada did here.
Related resources
Product Compliance · 2026-08-21
On 19 August, Health Canada recalled a custom-made roller shade for breaking a five-year-old cord rule: in the regulator's last compliance sweep, 43 of 44 window coverings failed it, and most of the failures were never imported at all
Product Compliance · 2026-08-25
On 20 August, CPSC told 376,974 households to stop using a carbon monoxide detector sold under 18 brand names: because the manufacturer refused to recall it, a public warning was the only tool the agency had left
Product Compliance · 2026-08-22
CPSC's ninth warning in ten months against a product banned since 2022: two of the earlier listings, pulled three weeks apart under different seller names, carried the identical manufacturer's model number
Product Compliance · 2026-09-21
On 10 September, US regulators recalled the same hair dryer brush twice under two different brand names for missing a device mandatory since 1991: three more sellers of the identical product, on two other marketplaces, only got a warning, with no refund
Try Cleo: free regulatory risk scan
See your regulatory landscape mapped in minutes. No signup, no credit card.